Introduction to Power System Protection
Sold by Ergodemedia, an authorized reseller of Authentic New & Used Books with Free US Shipping.
30-day returns by mail · Refunded to original payment method | support@ergodemedia.com
Shipping Information
- Free Standard Shipping — United States only
- Processing Time: 1–3 business days
- Estimated Delivery: 3–5 business days after dispatch via USPS / UPS
- Securely packed to ensure your book arrives in the described condition
- Tracking number sent via email once dispatched
- Taxes calculated at checkout. International shipping not available.
Returns & Refund
Returns accepted within 30 days of delivery. Returns are processed by mail. Refunds are issued to the original payment method within 5–7 business days of receiving the returned item.
Damaged, Defective or Misrepresented Item
Free return shipping by mail · Full refund to original payment method
Wrong Item Received
Free return shipping by mail · Full refund or replacement at your choice
Change of Mind
Return shipping at customer's expense · Book must be in the same condition as received · Refund to original payment method
Safety & Compliance
California Proposition 65 Warning
Some products sold on this website may expose you to chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
www.P65Warnings.ca.govBook Condition & Care Notice
Used books are graded and described accurately — condition details are listed on each product page. Books may contain previous owner's handwriting, highlights, or stamps unless stated as new. Store books away from direct sunlight and moisture to preserve their condition.
New books are sealed or unread. Used books are inspected before dispatch.
Product Authenticity & Notice
All books sold by Ergodemedia are 100% authentic, sourced directly from publishers and trusted distributors. Book condition is accurately graded and described. Some books may contain previous owner's markings or inscriptions.
Ergodemedia — Authentic New & Used Books. Free US Shipping. Delivered to Your Door.
Description
Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers The function of the CT is to reproduce in its secondary winding a current I that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0-5 ampere range for convenience of measurement. The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When |I| exceeds a specified pickup value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open. The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References.
Shop The Full Collection